Quiz: Radiation Quantities and Units A multiple-choice quiz consists of: 10 QuestionsQuestions are selected randomly from a collection of 18 questions. More Questions You will get deferent questions every time you take the quiz. Correct AnswersThere could be more than one correct answer, select all that apply.Skip QuestionsYou are allowed to scroll backward and forward before submitting your answers.10 MinutesThe quiz has a time limit. Time's up You can still submit your answers after the allowed period of time has ended . When ready, click Next to start the quiz. Name (Required) Email (Optional) Twitter (Optional) 1. A nuclear medicine department receives 375 mCi of Tc-99m in 4.5 ml bulk vial. If the macroaggregated albumin (MAA) kit is to be reconstituted with 30 mCi in 3 ml, how much saline should be added to the kit? 3.0 ml 3.6 ml 2.64 ml 1.64 ml None 2. If a 15 mCi of F-18 fluorodeoxyglucose (FDG) dose is needed for positron emission tomography (PET) scan at 1:00p.m., how much activity should be prepared at 10a.m.? 11 mCi 4.8 mCi 21.2 mCi 46.6 mCi None 3. At the time of preparation, a macroaggregated albumin (MAA) kit contained 30.5 mCi of Tc-99m. How much activity will remain after 5 hours and 30 minutes? 18.5 mCi 7.2 mCi 10.5 mCi 16.2 mCi None 4. 850 milligrays (mGy) are equal to? 85,000 rads 85 rads 8,500,000 rads 0.850 rad None 5. A radionuclide with a physical T% of 10 days is taken up by the liver and eliminated with a biological T% of 15 days. Which of the following is its effective T%? 2 days 10 days 25 days 6 days None 6. If 300 uCi of I-123 is used for an adult dose, what is the pediatric dose according to Young’s formula for a child who is 14 years old and weighs 30 kg? 173 uCi 250 uCi 185 uCi 162 uCi None 7. How much activity will be remaining at 2:30 p.m. if the dose of Tc-99m methylene diphosphonate (MDP) is calibrated to contain 25 mCi at 12:00 p.m. on the same day? 18.7 mCi 19.5 mCi 15.7 mCi 17.3 mCi None 8. Dose equivalency is being measured in units called: Rads Curies Rems Becquerels None 9. Xe-133, used during a ventilation/perfusion (VQ) scan has a physical half-life of 5.3 days and biological half-life is 0.37 min. What is the effective half-life of Xe-133? 5 s 3.7 min 0.37 min 5.3 min None 10. Which of the following is the unit of Absorbed Dose? Gray Roentgen Curie Becquerel None 1 out of 10 Time's upTime is Up! By Nasser AlMutairi|2021-09-20T13:16:59+03:00April 15th, 2021|Radiation Safety| شارك هذه الصفحة FacebookXLinkedInWhatsAppPinterestEmail About the Author: Nasser AlMutairi Senior Nuclear Medicine Specialist at Hafar Al-Batin Central Hospital, Founder of NuclearMed Website. Related Posts Quiz: Radiation Safety Quiz: Radiation Safety April 15th, 2021 | 0 Comments Leave A Comment Cancel replyComment Notify me of follow-up comments by email. Notify me of new posts by email. Δ
Leave A Comment